LV Switchgear · Distribution Boards

Switchgear & Distribution Panels

Where aluminium feeders meet copper busbar — a bolted joint that stays stable without paste, with EN 10204 2.2 on every shipment and 3.1 on request.

You are the one signing the routine verification

The IEC 61439 series splits the work in two. The original manufacturer brings the design verification with a certified system; the assembly manufacturer — the panel builder — puts the cabinet together, carries out the routine verification and signs it. The moment you depart from the certified configuration, the burden of proof moves with you.

There is one joint in that cabinet you cannot verify your way around: the incoming aluminium feeder cable landing on the copper busbar through a bolted joint. IEC 61439-1 allows a 70 K temperature rise at terminals at rated current. A direct Al/Cu contact builds an oxide film and starts galvanic corrosion; within a few years the junction shows up as a hotspot on a thermal survey and drifts out of the temperature budget under summer peak load. Antioxidant paste can be re-applied every few years — but that means booking a maintenance window, documenting the work and signing for it, which is not something anyone running a hospital, a data centre or a process plant wants on a recurring basis.

The trouble does not appear at handover. It appears two or three years later, on a thermographic survey, as a hot spot — on a document with your name on it.

In short

In a switchgear cabinet or distribution panel, the incoming aluminium feeder meets the copper busbar; a CUPAL transition plate or M6–M20 washer solves this bolted joint with no galvanic corrosion and no paste, staying within the 70 K temperature-rise limit of IEC 61439-1.

70K
IEC 61439-1 temperature-rise limit
1.2A/mm²
Cu current density (DIN 43671)
M6–M20
11 CUPAL washer sizes
5–10working days
Custom-cut production (quote within 24 h)

Which washer goes into the joint

Two numbers decide it: the bolt in the joint gives the thread size, and the conductor cross-section of the lug gives the outer diameter you need. Check the palm width separately — if it is wider than the outer diameter of the row you picked, step up to the next outer diameter. Net list prices are published per size on the CUPAL washer product page.

Bolt sizeM6
Outer Ø16 mm
Max. lug cross-section120 mm²
SKUICALCU6CS
Bolt sizeM8
Outer Ø18 mm
Max. lug cross-section120 mm²
SKUICALCU8CS
Bolt sizeM10
Outer Ø23 mm
Max. lug cross-section240 mm²
SKUICALCU10CS
Bolt sizeM10 (large)
Outer Ø26 mm
Max. lug cross-section300 mm²
SKUICALCU10CS2
Bolt sizeM12
Outer Ø26 mm
Max. lug cross-section240 mm²
SKUICALCU12CS2
Bolt sizeM12 (large)
Outer Ø30 mm
Max. lug cross-section400 mm²
SKUICALCU12CS
Bolt sizeM12 (extra)
Outer Ø46 mm
Max. lug cross-section500 mm²
SKUICALCU12CS3
Bolt sizeM16
Outer Ø35 mm
Max. lug cross-section500 mm²
SKUICALCU16CS
Bolt sizeM16 (large)
Outer Ø46 mm
Max. lug cross-section630 mm²
SKUICALCU16CS2
Bolt sizeM20
Outer Ø37 mm
Max. lug cross-section500 mm²
SKUICALCU20CS
Bolt sizeM20 (large)
Outer Ø46 mm
Max. lug cross-section630 mm²
SKUICALCU20CS2

What CUPAL does in the joint

CUPAL puts the whole transition into a single diffusion-bonded plate or washer, and the rule is the same everywhere: each face meets its own metal. In this cabinet the aluminium side faces the cable lug or terminal and the copper side faces the busbar; where the lug is the copper part and the bar is aluminium, the same washer goes in the other way up. Either way the electrochemical driver of galvanic corrosion — two dissimilar metals sharing an electrolyte at the joint — is removed at the contact itself. No paste, no annual re-torque, no oxide surprises on the thermographic survey. Tightening torque remains whatever the busbar and bolt manufacturers specify; CUPAL has no torque table of its own, and the rest of the fitting sequence is in the CUPAL installation guide.

Order without a minimum quantity, with net list prices per size and the distributor cross-reference (NEXANS, Mentavill), on the CUPAL washer product page.

The base material carries DIN 17007 / DIN 1787 designations (aluminium AL 99.5 / 3.0255, copper E1-Cu58 / 2.0065); EN 10204 2.2 with every shipment, EN 10204 3.1 on request. The material comes from an ISO 9001:2015 certified supply chain, and HIDRA-MIX Kft. has been supplying the Hungarian electrical industry since 1991.

What this looks like in numbers

70K
IEC 61439-1 temperature-rise limit on bolted joints
1.2A/mm²
Copper busbar current density (IEC 61439, DIN 43671)
70–110N/cm
CUPAL Al–Cu bond strength
2–4weeks
Custom order, EU door to door including transit

Where it fits in the cabinet

Four places in the cabinet where you will hit an Al/Cu joint — and the table above gives the SKU for the one you land on.

01 / 04

Incoming feeder → main busbar

The problem you need to solve. A three-phase aluminium feeder (e.g. 3×240 mm² Al) lands on the main copper busbar through a bolted lug. Thermally it is one of the hardest-worked joints in the cabinet under IEC 61439-1.

How CUPAL solves it. A CUPAL transition plate between the lug and the bar, cut to the existing bolt pattern. Al face to the lug, Cu face to the bar, standard M10/M12 hardware. Torque is set by the busbar and bolt manufacturers' specification — CUPAL has no torque table of its own.

02 / 04

Outgoing feeder: Cu busbar → Al cable to MCC

The problem you need to solve. The outgoing direction lands copper busbar on aluminium cable feeding a motor control centre or sub-distribution. Same Al/Cu bolted joint, often with stricter handover documentation.

How CUPAL solves it. A CUPAL washer between busbar and lug. One part, no extra tools, no paste — and the material ships with an EN 10204 certificate you can drop into the panel dossier.

03 / 04

N / PE equipotential bar

The problem you need to solve. In a multi-storey riser, aluminium neutral and PE conductors terminate onto the cabinet's copper bonding bar. Thermal cycling relaxes the bolted joint, oxide adds resistance.

How CUPAL solves it. A CUPAL transition plate between bonding bar and riser. Both bolted faces put like metal against like metal, so the joint no longer depends on the aluminium oxide film — there is no interface left to clean and re-paste on a cycle.

04 / 04

Brownfield retrofit

The problem you need to solve. A 10–20-year-old cabinet gets an Al feeder upgrade on capacity, but the original copper busbar stays. Catalogue parts do not always fit the old bolt pattern or the stack-up height.

How CUPAL solves it. A CUPAL plate cut to the existing pattern from a DXF, PDF or JPG drawing — quote within 24 hours, 5–10 working days in production. It installs without structural modification.

Compared to the usual alternatives

Four familiar approaches to the same bolted joint — what happens to it over time, and how much freedom you have on geometry.

ApproachCu lug + antioxidant paste
Initial joint behaviourAcceptable, drifts over time
MaintenanceNew paste + re-torque every 2–3 yrs
GeometryStandard lug footprints
ApproachSpecialty compression bimetal lug (imported)
Initial joint behaviourStable
MaintenanceNone
GeometryFixed, catalogue geometry
ApproachOver-sized pure copper conductor
Initial joint behaviourExcellent
MaintenanceNone
GeometryRemoves the joint, but the conductor run is re-specified
ApproachCUPAL washer or custom-cut plate
Initial joint behaviourStable
MaintenanceNone
Geometry11 stocked washer sizes, or any contour from DXF, PDF or JPG

Washer, lug or cut plate

The same material in four forms — the geometry of the joint decides which one belongs in it.

FormCUPAL washer (M6–M20)
When this is the oneA finished lug bolts onto the bar and the bolt pattern is fixed
Geometry11 stocked sizes, all 2 mm thick
AvailabilityFrom stock, 2–10 working days to delivery
FormCUPAL bimetal cable lug (ICALCU)
When this is the oneThe cable end itself has to change metal
Geometry109 SKUs — eye-lugs, butt-splices, pin lugs
AvailabilityFrom stock
FormCUPAL sheet, 500 × 500 mm
When this is the oneBar-to-bar transition, larger contact area
Geometry0.5 / 1.0 / 1.5 / 2.0 mm
Availability0.5 and 1.0 mm from stock; 1.5 and 2.0 mm 5–10 working days
FormCustom cutting
When this is the oneThe existing bolt pattern takes no catalogue part
GeometryAny contour from a DXF, PDF or JPG drawing
AvailabilityQuote within 24 h, 5–10 working days in production

What we supply, and what we don't

We have been supplying tooling and material to switchgear, busbar and cable-lug manufacturers and to lightning-protection contractors since 1991 — we supply into your bill of materials, we do not bid for your work. We do not build cabinets, and we do not sell enclosures, busbar systems, terminal blocks, circuit breakers or installation labour. One line item goes into your BOM: the copper-aluminium transition — as an M6–M20 washer, as an ICALCU bimetal cable lug, 109 SKUs from stock, as CUPAL sheet, 500 × 500 mm, or as a contour cut to size from your DXF, PDF or JPG drawing.

We do not sign the declaration of conformity for the cabinet either. EN 10204 2.2 — 3.1 on request — certifies the material; IEC 61238 and IEC 61439 apply to the assembly the part is fitted into, not to CUPAL itself. Under MSZ EN 61439 the routine verification belongs to the assembly manufacturer, and it stays there. What we add is the EN 10204 material certificate for your handover file and a summary of how the standards relate to one another.

One route falls outside ours: if the specification calls for a Cuponal busbar profile, that is a different supply chain — Cuponal is made by hydrostatic extrusion and exists only as long product (busbar, rod, profile, wire). If what you need is a Cu-Al transition as a sheet, a disc, a strip or a washer, that is CUPAL, and that is us.

If the retrofit bolt pattern takes no catalogue part, send us the drawing — DXF, PDF or JPG all work, and we quote within 24 hours. And if it is not cable onto bar but bar onto bar, the Al/Cu busbar transition is the closer page.

FAQs from panel builders

We supply all three, and the joint decides which one. If the copper lug is already crimped onto the cable and only the bolted interface is dissimilar, the washer is the part — 11 stocked sizes from M6 to M20, all 2 mm thick. If the cable end itself has to transition from aluminium to copper, that is a bimetal lug: the ICALCU range is 109 SKUs from stock, in tubular eye-lug, butt-splice and pin-lug form. Once a cabinet has a dozen of these joints, or the bolt pattern does not match any catalogue part, a plate cut to your drawing is the simpler answer. A lug is designed for one joint; a cut plate is made for the cabinet.
No. The diffusion bond is inside the material; on the outside, each face meets its own metal, so there is no shared electrolyte at the joint. Paste is not forbidden — just redundant.
Every shipment carries an EN 10204 2.2 declaration of conformity; an EN 10204 3.1 batch-specific inspection certificate is available on request — say so with the order. Our supplier works to ISO 9001:2015. Note what the certificate covers: EN 10204 certifies the material. IEC 61439 and MSZ EN 61439 apply to the finished assembly, not to CUPAL, and the routine verification stays with you as the manufacturer of the assembly. What we add to your handover file is the material certificate.
Two clocks run on a custom order: production and transit. A contour cut from your DXF, PDF or JPG drawing takes 5–10 working days in production, and we quote within 24 hours of receiving the drawing; allow 2–4 weeks from order to your door anywhere in the EU, transit included. The 500 × 2000 mm format is quoted the same way — we do not hold that size in stock. Stock material moves faster: all 11 washer sizes and the 500 × 500 mm sheet in 0.5 and 1.0 mm are held, 2–10 working days from order to delivery in Hungary, a little longer elsewhere in the EU. The 1.5 and 2.0 mm sheet gauges are made to order, 5–10 working days in production. If you are up against a date, call us before you order and we will tell you what is actually possible.
No. Standard M6–M20 bolted joints and a torque wrench; a spring washer if your detail calls for one. All 11 washer sizes are 2 mm thick, which fits the bolt length of most existing cabinet joints, and a larger outer diameter does not change the bolt length you need. Torque is set by the busbar and bolt manufacturers' specification — CUPAL has no torque table of its own.

Applicable standards for this field

IEC 61439-1
IEC 61439-2
DIN 43671
VDE 0660-600
MSZ EN 61439-1

Get free expert advice

Cannot find your application? Describe it to us and we will advise.